MRLS RAK - 12 cal. 128mm TECHNICAL DETAILS
Caliber | 128 mm | |
Maximum range with rocket 128 mm M91A1,A2 | 8540 m | |
Number of tubes | 12 | |
Tube length | 1200 mm | |
Horizontal field of action | ± 15° | |
Vertical field of action | -1° to 46° | |
Fire modes | burst fire | 12 rockets in 9,6 s |
single rocket fire | 1 rocket in 1 s | |
Remote controller cable length | 25 m | |
Battery | 12 V / 7 Ah | |
Battery charging voltage | DC external source | 12 - 24 V |
AC external source | public electric grid: 110 - 220 V | |
Charging current | up to 1A | |
Impulse current | up to 2,1 A | |
Impulse length | 55 ms | |
Launcher mass in transport | 720 kg | |
Launcher mass in firing position | unloaded weapon | 695 kg |
loaded weapon | 975 kg | |
Spare parts and accessories box weight | 25 kg | |
Towing eye force | 450 N | |
Launcher length in transport configuration | trails closed | 3740 mm |
trails extended | 3785 mm | |
Clearance, in transport configuration | 270 mm | |
Track width | 1550 mm | |
Launcher width in transport configuration | 1710 mm | |
Width in combat configuration (trails extended) | 2890 mm | |
Height of empty launcher | 1300 mm | |
Height in combat configuration (46° elevation) | 1885 mm | |
Wheels dimensions | 165R13 | |
Time to load the launcher (rockets prepared in advance, equipped with fuses and armed) | 1 min 20 sec | |
Time to convert launcher from transport configuration to the firing configuration (including launcher loading) | up to 3 min 30 sec | |
Time to convert launcher from transport configuration to the firing configuration (rockets already loaded) | up to 1 min 30 sec | |
Time to convert launcher from firing configuration to the transport configuration (launcher loaded) | up to 1 min | |
Angular division | 64 - 00 | |
Traversing and elevation mechanism | mechanical | |
Firing control unit electricity usage - fire control unit switched on | up to 80 mA | |
Firing control unit electricity usage - button ARM pressed | up to 190mA | |
Firing control unit electricity usage - impulse usage with ARMED pressed | up to 2,4mA | |
Operating temperature range | -30° to 50°C |